ANR2324W Audit volume process terminated for volume volume name - thread resource not
available.
Explanation: During processing of an AUDIT VOLUME command for the
volume shown, the server cannot start a thread for the audit process.
System Action: The AUDIT VOLUME command is ended.
User Response: Reissue the AUDIT VOLUME command. If the error persists, it
may indicate a shortage of server memory.
ANR2325W Audit volume process terminated for volume volume name - sufficient memory
is not available.
Explanation: During processing of an AUDIT VOLUME command for the
volume shown, the server does not have enough memory available to complete the
command.
System Action: The AUDIT VOLUME command is ended.
User Response: If necessary make more memory available to the server.
ANR2326W Audit volume process terminated for volume volume name - lock conflict
detected.
Explanation: During processing of an AUDIT VOLUME command for the
volume shown, the server cannot obtain a required lock.
System Action: The AUDIT VOLUME command is ended.
User Response: Reissue the command.
ANR2327W Audit volume process terminated for volume volume name - internal server
error detected.
Explanation: During processing of an AUDIT VOLUME command for the
volume shown, an internal server error occurs.
System Action: The AUDIT VOLUME command is ended.
User Response: Contact your service representative.
ANR2332W Object object.ID deleted by another process during execution of an AUDIT
VOLUME command for volume volume name.
Explanation: During processing of an AUDIT VOLUME command, a data storage
object was deleted from the volume that was being audited. The AUDIT VOLUME
process was unable to locate this object on the specified volume. Normally, this