Library Operation
Installation and Operation
73
Replacing a single cartridge
As described in this section, you can use several different methods
to replace single cartridges without opening the library door.
Use the Extend/Retract E/E option to insert or remove
cartridges through the entry/exit port.
Use the Remove Cartridge option to remove the cartridge.
Use the Insert Cartridge option to replace the cartridge.
➤ Important Do not open the library door to
replace individual cartridges. Opening and closing
the library door causes the library to update the
cartridge inventory, which takes approximately 2½
to 5 minutes.
Using the Extend/ Retract E/ E option
1. Make sure that security is disabled (see page 60).
2. From the Main Menu, select Extend/Retract E/E. The library
extends or retracts the entry/exit port transport arm,
depending on its current position.
3. Insert the cartridge into the entry/exit port and press
>(QWHU @
; or,
remove a cartridge by pressing down on the entry/exit port
PUSH tab, as shown in the following figures.