Roland AR-3000R MP3 Player User Manual


 
48
Recording Audio
Next, if you’re making the setting for the “Trig Level”, proceed to step 2
of the procedure for making the trigger recording setting.
Trig Level (Trigger Recording Settings)
A method for starting recording automatically when audio higher than the
trigger level (the volume level for starting recording) is input is called
trigger recording. The following four types of trigger recording settings are
available.
OFF:
Trigger recording is not performed.
LOW:
Recording starts when audio at a low volume level is input (-45
dBm).
MID:
Recording starts when audio at an intermediate volume level is
input (-36 dBm).
HIGH:
Recording starts when audio at a high volume level is input (-27
dBm).
( ): Trigger level
* When you are recording from microphone input with the trigger level set at
“LOW,” recording may be inadvertently started by ambient noise. If this happens,
change the trigger level to MID or HIGH, or carry out recording in a quieter
location.
* If you quit recording without waiting for trigger recording to start, no phrase is
created.
Procedure for the Trigger Recording Setting
1
Put the unit into recording standby.
2
Turn the SELECT dial to choose “Trig Level,” then press the
dial.
3
Turn the SELECT dial to choose the Trig Level (OFF, LOW,
MID, or HIGH), then press the ENTER button.
* Please be aware that if you press the SELECT dial instead of the ENTER button, the
setting is not confirmed.
Adjusting the
Recording Level
Input audio from the connected device and adjust the recording level.
AR-3000R_e.book 48 ページ 2010年3月18日 木曜日 午後2時6分