MIDI Implementation
Appendices
* Not received when recording mode is not “Standby”.
* The same processing will be carried out as when Start is received.
Stop
status
FCH
* Not received when recording mode is not “record”.
3.4 Messages received for detecting
trouble in MIDI connection.
System Realtime message
Active Sensing
Status
FEH
* When Active Sensing is received, the unit will begin monitoring the intervals of all
further messages. While monitoring, if the interval between messages exceeds 400 ms,
the same processing will be carried out as when All Sounds Off, All Notes Off and Reset
All Controllers are received, and message interval monitoring will be halted.
4. Transmit data (MIDI Recorder Section)
When AR-3000R is in MIDI Recorder mode, MIDI Messages is not transmitted.
5. Exclusive Communication
Exclusive message model IDs that can be used on the AR-3000R are OOH, 00H, and 37H
(AR-3000R). The Device Id can be set to 00H to 1FH.
Only received when AR-3000R is in Media Player Section.
Data Set 1 DT1 (12H)
Byte Description
F0H Status of System Exclusive Message
41H Universal System Exclusive Message Real time Header
dev device ID (dev : 00H--1FH)
mdl Model ID (mdl : 00H, 37H) AR-3000R
12H Command ID (DT1)
aaH address MSB
::
ccH Address LSB
ddH Data
::
kkH Data
sum Check Sum
F7H EOX (End of System Exclusive Message)
5.1 Parameter Address Map
This map indicates address,size, data (range), Parameter, Description,and default Value of
parameters which can be transferred using “Data Set1(DT1).”
All the numbers of address, size, Data, and default Value are indicated in 7-bit
Hexadecimal-form.
(AR-3000R Model ID=00H,37H)
Address Block Map
An outlined address map of the Exclusive Communication is as follows;
Exclusive Address Table for recording setting
Address(H) SIZE(H) DATA(H) Parameter Description
===================================================================
00 00 10 00 00 08 00 - 07 Phrase Number upper 4bits
11# 00 - 7f Phrase Number lower 7bits
12# 00 - 05 Grade 0:ANNOUNCE
1:LONG2
2:LONG1
3:STANDARD
4:HIGH
5:S-HIGH
13# 00 - 04 R-DAC mode 0:Linear
1:Mode1
2:Mode2
3:Mode3
4:H-LINEAR
14# 00 - 01 REC type 0:MONO
1:STEREO
15# 00 - 03 REC Trigger Level 0:OFF
1:LOW
2:MID
3:HIGH
16# 00 - 03 REC Source 0:LINE-IN
1:LINE+MIC-IN
2:DIGITAL-IN
3:MIDI-IN
17# 00 - 01 TimeBase 0:192
1:240
===================================================================
Phrase number DATA(H)
A0001-A1000 00 00 - 07 67
B0001-B1000 07 68 - 0H 4F
* Only received packet data.
* When reception of this packet is completed, the AR-3000R goes into REC PAUSE mode.
However, if the phrase already exists, the AR-3000R ignores this SysEx message.
(AR-2000 compatible)
Address(H) SIZE(H) DATA(H) Parameter Description
===================================================================
00 00 00 00 00 08 00 - 07 Phrase Number upper 3bits
01# 00 - 7f Phrase Number lower 7bits
02# 00 - 04 Grade 0:ANNOUNCE
1:LONG2
2:LONG1
3:STANDARD
4:HIGH
03# 00 - 02 R-DAC mode 0:Linear
1:Mode1
2:Mode2
04# 00 - 01 REC type 0:MONO
1:STEREO
05# 00 - 03 REC Trigger Level 0:OFF
1:LOW
2:MID
3:HIGH
06# 00 - 01 REC Source 0:ANALOG-IN
(MIDI REC OFF)
1:MIDI-IN
(MIDI REC ON)
07# 00 - 01 TimeBase 0:192
1:240
===================================================================
Phrase number DATA(H)
A0001 - A0500 00 00 - 03 73
B0001 - B0500 03 74 - 07 67
* Only received packet data.
* When reception of this packet is completed, the AR-3000R goes into REC PAUSE mode.
However, if the phrase already exists, the AR-3000R ignores this SysEx message.
* ANALOG-IN for REC Source is set to LINE-IN on the AR-3000R.