IBM SAN384B Portable Media Storage User Manual


 
internal temperature range exceeds the operating ranges of the components,
the LEDs, error messages, and Fabric Watch alerts will indicate a problem.
Use the tempShow command or Fabric Watch commands to view
temperature status.
Fibre channel port specifications
The Fibre channel ports in the SAN384B support full duplex link speeds at
10.51875, 8.50, 4.25, 2.125, or 1.0625 Gbps inbound and outbound, automatically
negotiating to the highest common speed of all devices connected to the port.
The ports are compatible with optical SWL (short wavelength: approximately 850
nm), optical LWL (long wavelength: approximately 1310 nm), and Extended Long
Wavelength (ELWL) laser transmitter SFPs, SFP+, mSFP (FC8-64 only), and XFPs
(FC10-6 only) (approximately 1550 nm). The strength of the signal is determined by
the type of SFP, SFP+, mSFP or XFP in use. mSFPs support only SWL.
The ports are universal and self-configuring, capable of becoming F_Ports (fabric
ports), FL_Ports (fabric loop enabled), or E_Ports (expansion ports).
The ports meet all required safety standards.
Power specifications
DANGER
Multiple power cords. The product might be equipped with
multiple power cords. To remove all hazardous voltages,
disconnect all power cords. (L003)
The power subsystem is a redundant +48V DC power distribution system with a
provision for up to two 2000-watt, 48V DC bulk power supplies. Two bulk power
supplies produce the intermediate distribution voltage in the distributed power
system.
The power specifications listed in Table 25 are calculated for fully-loaded systems
with two power supplies, four FC8-64 port blades, two CP8 blades, two CR4S-8
blades, and two blower assemblies. The use of application blades will consume
additional power.
Table 25. Power specifications
Specification Value
Voltage Range: 85 - 264 VAC Auto-volt, Nominal:
100 to 240 VAC (auto-sensing)
Power supply output (each) Low line (85- 132 VAC), 1000W; High line
(180 - 264 VAC), 2000W
Input frequency range Range: 47-63 Hz; Nominal: 50 - 60 Hz
AC inrush Maximum 20A peak
124 SAN384B Installation, Service, and User Guide
|
|
|
|
|
|