NEC IS004-13E Portable Media Storage User Manual


 
Chapter 3 Basic Functions
II-39
(iv) State
Displays the operating state in component related to controller in any of following at “State” column.
Ready: Component of controller is in normal operation
Attn.(nolicense): The program product “BaseProduct” has not been installed.
(Displayed only for the Host Director)
Attn.(rebuilding): Component of controller is in the data rebuilding state
(Displayed only for Cache Module)
Attn.(charge): Component of controller is being charged
(Displayed only for Battery Backup Unit)
Offline: Component of controller is separated or does not exist
Fault: “Fault” occurred in component of controller
(If component type is Temperature Alarm, indicates the abnormal temperature)
(v) Others
Displays supplement information in each component at “Others” column optionally. Displays the cache module
capacity, port number and protocol information in controller information.
• Cache module capacity
If component type is “Cache Module”, the cache module capacity is displayed at “Others” column.
• Port number
If component type is “Host Director”, “Replication Director”, or “Disk Director”, port number (2 hexadecimal
digits) that applicable director possesses is displayed at “Others” column.
• Protocol information
If component type is “Host Director”, the protocol information of the target director is displayed following the
port number at “Others” column.