TASCAM HS-4000 75
10 – Internal settings
T/C page
Make settings related to time code on this page.
Set to free run
Set to jam sync (and free once)
STATUS
This shows the time code generator mode of the unit and the
time code frame type of the currently loaded project.
GENERATOR
The top line shows the current time code generator.
The bottom line shows the user bits (
UB).
Touch the
GENERATOR item EDIT button or the user bits (UB)
display area to open the
T/C USER BITS screen.
When the time code generator is in free run mode, touch the
RESTART button to reset the time code of the time code
generator to the start time.
TC IN
The top line shows the time of the input time code and the
frame type. The bottom line shows the user bits (
UB) of the input
time code.
In Free Run mode, touch the
CAPTURE button to capture the
current time code and set it as the time code of the time code
generator.
If the time code generator mode is Free Once or Jam Sync, the
capture status (
WAITING) indicator lights green when waiting
for time code, and it turns off after time code is captured.
START TIME
When you touch the GENERATOR item RESTART button, the
time when the time code restarts is shown.
Touch the
START TIME item EDIT button or the START TIME
display area to open the
START TIME screen.
SETUP page
Make settings related to the time code generator on this page.
STATUS
This area shows the currently loaded project’s time code frame
type.
TC GEN MODE
Use the buttons to set the time code generator mode.
FREE RUN button:
The time code generator runs on its own.
FREE ONCE button:
After the input time code is captured once, the unit starts
free run mode.
TIME OF DAY button:
If you conduct any of the following operations, the time will
be captured from the internal clock and free run mode will
start.
• Turn the power on
• Set
TC GEN MODE to this mode
• Reset the internal clock
JAM SYNC button:
When time code is input, the unit synchronizes to it. If time
code input is interrupted, the unit enters free run mode.
REGEN button:
The unit synchronizes to the input time code.
REC RUN button (default):
The time code generator only functions during recording. At
all other times, the time code generator stops.
Frame Type
Set the time code frame type of the currently loaded project.
Setting buttons:
23.976F, 24F, 25F, 29.97DF (default),
29.97ND, 30DF, 30ND