Setup: Item Settings
111
Setup
This menu sets buttons available on the key panel in REMOTE mode, switches display of the CTL counter display between 12
and 24-hour clock display, sets superimposed display, character displays in superimposed display, SETUP-MENU and other
displays, sets recording formats, sets the formats that can be added to the play list and sets the time of the internal clock.
* An underlined setting
indicates an initial value.
BASIC
Item Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
001 LOCAL ENA
0000
0001
0002
DIS
STOP
ENA
Restricts the number of buttons on the key panel that are available when the CONTROL
switch is set to REMOTE.
0: No buttons are available.
1: Only the STOP button is available.
2: All buttons are available.
002 CTL DISP
0000
0001
±
12h
24h
Switches the CTL counter display between 12 and 24-hour clock display.
0: 12-hour clock display
1: 24-hour clock display
003 REMAIN SEL
0000
0001
0002
0003
OFF
2L
1L
R/TTL
Specifies whether to display the remaining time or total time via the VIDEO MON connector
and via superimposed display of the LCD panel.
0: No display.
1: Displays remaining media time on the second line.
2: Displays remaining media time on the first line.
3: Displays the remaining media time on the first line and total media time on the second
line.
NOTE:
•These functions are not displayed when “2L” is selected and “TIME” is set in setup
menu No. 006 (DISPLAY SEL).
•Total tape time is not displayed when “R/TTL” is selected and “TIME” is set in setup
menu No. 006 (DISPLAY SEL).
006 DISPLAY SEL
0000
0001
0002
0003
0004
0005
0006
0007
0008
0009
TIME
T&STA
T&S&M
T&RT
T&YMD
T&MDY
T&DMY
T&UB
T&CTL
T&T
Specifies the output of the VIDEO MON connector or what is displayed in the
superimposed display of the LCD panel.
Here, “data” indicates the CTL/TC/UB value selected with the COUNTER button.
0: Data only
1: Data and operating status
2: Data, operating status and mode
3: Data and REC TIME
4: Data and REC DATE (year/ month/day)
5: Data and REC DATE (month/day/year)
6: Data and REC DATE (day/month/year)
7: Data and user bit
However, when UB is selected with the COUNTER button, the time code is indicated after
the user bit.
8: Data and CTL
However, when CTL is selected with the COUNTER button, the time code is indicated after
CTL data.
9: Data and time code
NOTE:
An error message appears in the superimposed display if a warning or error occurs
when T&S&M is selected.
007 CHARA H-POS
0000
|
0004
|
0016
0
|
4
|
16
Specifies the horizontal character position output via the VIDEO MON connector or
displayed in the superimposed display of the LCD panel.