For Long and Trouble-Free Operation: Error Messages
157
For Long and Trouble-Free Operation
HDD
HDD CAPACITY
FULL!
Not enough space left on the hard disk. There is not enough space on the connected hard
disk. Use a new hard disk or formatted hard disk.
TOO MANY
PARTITIONS!
There are too many partitions. Hard disks can handle up to 23 partitions. Use a new
hard disk or formatted hard disk.
HDD
DISCONNECTED!
The unit is not connected to a hard disk. Reconnect the USB cable. If the hard disk does not
operate normally, turn it off and turn it back on again.
CANNOT FORMAT! The hard disk cannot be initialized. Connect another hard disk drive.
TOO MANY
TARGETS!
Multiple devices are connected. Disconnect devices, turn off the unit and turn it back
on again.
UNKNOWN DEVICE
CONNECTED!
The connected DVD drive is not compatible. Disconnect devices, turn off the unit and turn it back
on again.
CANNOT ACCESS
TARGET!
An error occurred during hard disk access. Check hard disk status and connection.
CANNOT
RECOGNIZE HDD!
The destination target cannot be properly
recognized.
Reboot the hard disk or connect a different hard
disk.
CANNOT ACCESS
CARD!
An error occurred during P2 card access. Check P2 card.
MISMATCH
COMPONENT!
Copying cannot be made because the
destination card is in the wrong format.
Use a P2 card with appropriate capacity.
P2 CARD IS
UNFORMATTED!
The P2 card is not formatted. Use a formatted P2 card.
CARD IS EMPTY!
CANNOT COPY!
The P2 selected for copying is empty. Copying is not performed since the card is empty.
VERIFICATION
FAILED!
The compare check after copying failed. Copy the data again.
PLEASE FORMAT P2
CARD!
This warning indicates that data could not be
imported from a hard disk to a P2 card because
the P2 card contained recorded data.
You cannot copy to a P2 card that contains data.
Format the card on a P2 device and copy again.
On-screen
keyboard
CANNOT CHANGE! An attempt was made to change PERSON when
no text memo had been entered.
First enter a text memo.
CANNOT SET!
INVALID VALUE!
The entered value is invalid. Enter a valid value.
Play list
NO FILE! The specified file does not exist. Use SAVE AS to save or insert a normally operating
card.
READ ONLY
PLAYLIST VERSION!
The play list file is opened as read only because
it is in a different version.
Play lists created on the AJ-SPD850 can only be
opened as read only files. To edit such files on this
unit save them out.
CANNOT FIND CLIP! Specified clip could not be found. Insert the card with the clip.
INCLUDE MULTI
FORMAT!
The files are not in the same format. Play list files in different formats cannot be loaded.
READ ONLY 100
EVENTS!
The play list file exceeds the upper limit on
events.
The upper limit on events is 100 events. Files are
opened as read only.
Item Message Description Measure