![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/81/6812bfb6-3f47-41b5-aa4a-2081ad189b9b/6812bfb6-3f47-41b5-aa4a-2081ad189b9b-bg51.png)
2-23
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter 2 Shelf Management Commands
cnfclksrc
Attributes
Examples
Configure the E1 clock at the upper connector of the PXM-UI S3 as the primary source. Configure
subport (logical port) 10 on the line of the AXSM-1-2488 in slot 3 as the secondary. For the secondary
source on the AXSM, note the locations of the periods and colons. Upon successful execution, the
system displays a confirmation message.
pinnacle.7.PXM.a> cnfclksrc primary 7.35 -bits e1
Clock Manager has been successfully executed.
pinnacle.7.PXM.a> cnfclksrc secondary 3:1.1:10
Clock Manager has been successfully executed.
Configure a primary network clock to revert to the highest priority E1 clock source after recuperation
from a failure. Upon successful execution, the system displays a confirmation message.
pinnacle.7.PXM.a> cnfclksrc primary 7.36 -bits e1 -revertive enable
Clock Manager has been successfully executed.
Log: log State: active Privilege: GROUP1