Chapter 6 Logical Node, Port, and Signaling Commands
cnfsig
cnfsig
Configure Signalingconfigures signaling timers and crankback attempts for a port.
The cnfsig command lets you configure signaling timers for a port whether the port is up or down. The
new configuration applies to new incoming calls while existing calls remain intact. In addition to
standard timers, this command lets specify the maximum number of crankbacks that PNNI can attempt
at a port. You must specify at least one of the optional parameters.
Cards on Which This Command Runs
PXM45
Syntax
cnfsig <portid>
[-t301 t301-timer ]
[-t303 t303-timer ]
[-t308 t308-timer
]
[-t310 t310-timer
]
[-t316 t316-timer
]
[-t317 t317-timer
]
[-t322 t322-timer
]
[-t397 t397-timer
]
[-t398 t398-timer ]
[-t399 t399-timer
]
[-maxcrbk value
]
Syntax Description
portid The portid is the PNNI physical port. The format is
[shelf.]slot[:subslot].port[:subport]. See also PNNI Format, page 6-4.
-t301 The T301 timer.
Range: 150240 seconds
Default: 180
-t303 The T303 timer.
Range: 48 seconds
Default: 4
-t308 The T308 timer.
Range: 2045 seconds
Default: 30