Sonic Alert DCP301 Clock Radio User Manual


 
Chapter 8. PROGRAM SETUP
8-13
Inserting and deleting segments
(1) In the setting display state, move to the pattern item of the segment where the seg-
ment is to be inserted or deleted on the programming map.
(2) If you press
FUNC
+
ENT
, the display changes to confirm insertion of the segment,
and “I N S .” is displayed blinking in the upper display.
(3) If you press , the display changes to confirm insertion of the segment, and “I N S .
is displayed blinking in the upper display.
If you press , the display changes to confirm deletion of the segment, and “D E L .
is displayed blinking in the upper display.
(4) If you press
ENT
while “I N S .” is displayed on the upper display, the segment is
inserted.
If you press
ENT
while “D E L .” is displayed on the upper display, the segment is
deleted.
(5) The DCP301 returns to the setting display state.
Display (inserting segment)
Display (deleting segment)
When you insert a segment, a new segment is automatically created at the currently
displayed segment No., and all segment Nos. onward are incremented by one. The
setting of the inserted segment is as follows:
SP setting value: Same value as original segment before the new segment was in serted
Time setting value: 0:10
Events, time events and G.Soak are not set, and the PID set No. is set to 0.
If you try to insert a segment in a program already containing 30 segments, pressing
ENT
will not insert the segment.
When you delete a segment, the next segment shifts down to the currently displayed
segment No. and subsequent segment Nos. are decremented by one.
When you delete the last segment, the display changes to “- - - -” indicating that noth-
ing is set.
Segments cannot be inserted or deleted from currently running (RUN, HOLD, FAST,
END) programs.
Program No. Segment No.
Pattern
tendency
EV1 to EV3 and T1 to T5 all out
I N S.
Program No. Segment No.
Pattern
tendency
EV1 to EV3 and T1 to T5 all out
D E L
.