Sonic Alert DCP301 Clock Radio User Manual


 
Chapter 8. PROGRAM SETUP
8-10
Setting up G.Soak (guarantee soak) items
(1) In the setting display state, move to the G.Soak item of the segment to be set up on the
programming map.
(2) If you press
ENT
, the lower display starts blinking to indicate start of entry to the
No.1 setup.
(3) Press , , or to set to the G.Soak width setting.
Setting range: 0 to 1000U
(4) When you press
ENT
, blinking on the lower display stops.
(When
FUNC
+
CLR
are pressed, the lower display returns to “- - - -” and blinking
stops.)
Display
G.Soak setting value
Program No. Segment No.
Pattern
tendency
EV1 to EV3 and T1 to T5 all out
G. S.
“- - - -” is displayed for the setting values in non-set segments.
The G.Soak function does not work in non-set segments.
When setup data C 7 0 is set to 1, G.Soak items on the programming map are skipped
and not displayed.
Setting up G.Soak time-out items
(1) In the setting display state, move to the G.Soak time-out item of the segment to be set
up on the programming map.
(2) If you press
ENT
, the lower display starts blinking to indicate start of entry to the
No.1 setup.
(3) Press , , or to set to the G.Soak time-out width setting.
Setting range: 0:00 to 99:59 (h:min/min:s)
0.0 to 599.9 (0.1s)
(Select either of h:min or min:s as the time unit is setup data C64.
“:” is substituted by “.” as it cannot display.)
(4) When you press
ENT
, blinking on the lower display stops.
(When
FUNC
+
CLR
are pressed, the lower display returns to “- - - -” and blinking
stops.)
Display
“- - - -” is displayed for the setting values in non-set segments.
The G.Soak time out function does not work in non-set segments.
When setup data C 7 0 is set to 1, G.Soak time-out items on the programming map are
skipped and not displayed.
G.Soak time -out setting value
Program No. Segment No.
Pattern
tendency
EV1 to EV3 and T1 to T5 all out
G. S. t O