Sony MDS-B6P MP3 Player User Manual


 
Command Descriptions
Appendix
A-14 Appendix
The tracks can be set for each program area.
(program area 1-25).
In this case, set the track order and program
area.
DATA: 4 (2)
DATA1 (10, 1)
DATA2 (**, 100)
Track No. (001 to 255) (DATA1: 0FFH)
(DATA2: ** for PGM SENSE)
DATA3 (10, 1) track order (STEP) (01 to 25)
DATA4 (10, 1) program area (00 to 39)
Note
If DATA3 and DATA4 are omitted (DATA: 2),
the program area is 00, and the tracks are
assigned sequentially to the area where no track
number has been assigned.
RETURN command: 0A4H
MULTI ACCESS PRESET
Command: 025H
Function : Registers tracks for multi-access function
into the slot.
DATA: 3
DATA1 (10, 1)
DATA2 (**, 100) : (track number 001 to 255)
DATA3 (10, 1) : slot No. 1 to 10
DATA1 : 0FFH for sense
RETURN command: A5H
Notes
Set from the slot No.1. If you set from other
than the slot No.1, Tr 1 is assigned to the slot
which has not assigned a track.
If you set the slot which has already been
assigned a track, it will be overwritten and the
previous setting will be lost.
This command overwrites only the specified
slot and the settings in the other slots remains.
If you want to set fewer slots than in the
previous setting, clear the slots using the
command 2DH before setting (see the
example below).
Example:
Previous setting: /1-2-3-4-5/
If you want to assign Tr 9, 8, and 7 to the slot 1,
2, and 3 respectively without clearing the slots
using the command 2DH, the slot No.1, 2, and 3
are overwritten and the slot No.4 and 5 remain,
resulting the setting of “/9-8-7-4-5/”. If you
clear the slots using the command 2DH before
setting, the setting results in “/9-8-7/.”
NEXT AMS SET
Command: 026H
Function : Sets the Next AMS function.
DATA: 3
DATA1: (10, 1)
DATA2: (**, 100)
: Tr No. 001-255
: Tr No. 001-255 (when playback mode
is continuous play)
: slot No. 1-10 (when playback mode is
multi access play)
: step No. 1-25 (when playback mode is
program play)
DATA3: 000H : next AMS off
: 001H : next AMS on
DATA1: 0FFH for sense
RETURN command: A6H
Notes
To set the Next AMS function, set the DATA1
or DATA2 to “Tr No. DATA3 = 01H.”
To change the Tr No. setting, set the Tr No.
DATA3 to 01H you want to change to
DATA1 or DATA2.
To turn the Next AMS off, set the DATA3 =
00H.
PGM MODE SET
Command: 02CH
Function : Sets the data in a specific program area for
program play.
DATA: 2 (1)
DATA1
000H : PROGRAM SET
001H : PROGRAM SET PAUSE
002H : PROGRAM SET PLAY (active only
when the AUTO PAUSE and AUTO CUE
functions are off)
0CCH : PROGRAM CLEAR (Program area
= 00, if there is no DATA2)
0EEH : PROGRAM MODE RESET
(There is no DATA2)
(This command is accepted in the STOP
mode only)
0FFH : PROGRAM MODE SENSE (There is
no DATA2)
DATA2 (10, 1)
Program area (00 to 39)
(In the case of PROGRAM CLEAR command,
the program area = 0AA means that all program
areas are cleared.)