Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
95
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
P 09SSMM00 2 0900MM00
-
Controller Module#m(zz xxHz) SAS Port Fault
<pppppppppppp ssssssssss rrrrr>
These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.
CM SAS Port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 0ASSMM0p 20A00MM0p
-
Controller Module#m(zz xxHz) BE Expander
Port#p Fault <pppppppppppp ssssssssss rrrrr>
CM BE Expander Port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 2)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 0BSSMM00 2 0B00MM00
-
Controller Module#m(zz xxHz) Cache(MEM)
Fault <pppppppppppp ssssssssss rrrrr>
CM memory is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 0CSSMM00 2 0C00MM00
-
Controller Module#m(zz xxHz) Flash ROM Fault
<pppppppppppp ssssssssss rrrrr>
CM Flash ROM is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID
Trap
Sensor
Info
Lower: Description