Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
106
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
*1: This row indicates TrapWarningInfo for Trap No. 5 and TrapSensorInfo for Trap No. 6.
J C3SSMM00 5 0B00MM00 0x00 Controller Module#m(zz xxHz) Cache(MEM)
Correctable Error <pppppppppppppppppp
ssssssssssss rrrrrr>
These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.
Many correctable errors occurred in the CM memory.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
J D200dd0n 5D200dd0n 0x00 Power Supply Unit DE#dd/PSU#n Warning
<pppppppppppp ssssssssss rrrr>
PSU error is detected.
dd: DE-ID ("00" for a controller enclosure)
n: PSU number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
J DASSdd00 6 DA00dd00 1 DE Exhaust temperature DE#dd Warning
DE exhaust temperature error (Warning) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
J DBSSdd00 6 DB00dd00 1 DE Intake temperature DE#dd Warning
DE intake temperature error (Warning) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID (*1) Lower: Description