Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
94
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
A.2.2 Error Messages
This section describes the messages that are sent when the severity is Error for each type of
event.
Error message list
When the event type is "P"
The following messages are sent when components fail or degrade or when a temperature
error is detected.
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID
Trap
Sensor
Info
Lower: Description
P 01SSMM00 2 0100MM00
-
Controller Module#m(zz xxHz) Fault
<pppppppppppp ssssssssss rrrrr>
These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.
CM is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 06SSMM00 2 0600MM00
-
Controller Module#m(zz xxHz) BE Expander
Fault <pppppppppppp ssssssssss rrrrr>
CM EXP is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
P 08SSMM0p 2 0800MM0p
-
Controller Module#m(zz xxHz) DI Port#p Fault
<pppppppppppp ssssssssss rrrrr>
CM DI Port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version