Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
118
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
06 FB 80 SMART is reported from the 3.5 inch SAS Disk. These sense codes are notified when
"Disk reported a Warning" is enabled
for Warning Level in the event
notification setting.
They are not notified during
maintenance operations.
06 FB 81 SMART is reported from the 2.5 inch SAS Disk.
06 FB 90 DE Expander error is detected. These sense codes are notified when
"Module reported a Warning" is
enabled for Warning Severity Level in
Setup Event Notification.
They are not notified during
maintenance operations.
06 FB 91 DE Expander Port error is detected.
06 FB 0B Many correctable errors occurred in the CM memory.
06 FB D2 PSU error is detected.
06 FB DA DE exhaust temperature error (Warning) is detected.
06 FB DB DE intake temperature error (Warning) is detected.
06 C1 01 CM is rebooted
Sense code
Description Remarks
SK ASC ASCQ