Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
104
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
J 80SSdd0N 5 8000dd0N 0x00 Disk Drive DE#dd-Disk#n(SAS xxxGB yykrpm
ccccccc) SMART <pppppppppppp ssssssssssss
rrrr>
These messages
are notified when
"Disk reported a
Warning" is enabled
for Warning Level in
the event
notification setting.
They are not notified
during maintenance
operations.
SMART is reported from the 3.5 inch Disk.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
N: Disk slot number (0 – b (hexadecimal))
n: Disk slot number (0 – 11 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot spare
(Spare))
pp...: Component number
ss...: Serial number
rr...: Version
J 80SSdd0N 5 8000dd0N 0x00 Disk Drive DE#dd-Disk#n(SAS xxxGB yykrpm
ccccccc) Warning <pppppppppppp ssssssssssss
rrrr>
3.5 inch Disk error is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
N: Disk slot number (0 – b (hexadecimal))
n: Disk slot number (0 – 11 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot spare
(Spare))
pp...: Component number
ss...: Serial number
rr...: Version
J 81SSddNN 5 8000ddNN
0x00 Disk Drive DE#dd-Disk#nn(SAS xxxGB yykrpm
ccccccc) SMART <pppppppppppp ssssssssssss
rrrr>
SMART is reported from the 2.5 inch Disk.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
NN: Disk slot number (0 – 17 (hexadecimal))
nn: Disk slot number (0 – 23 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot spare
(Spare))
pp...: Component number
ss...: Serial number
rr...: Version
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID (*1) Lower: Description