Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
117
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
04 F1 90 DE Expander is disconnected. These sense codes are notified when
"Module was broken" is enabled for
Error Severity Level in the event
notification setting.
They are not notified during
maintenance operations.
04 F1 91 DE Expander Port is disconnected.
04 F1 D2 PSU is disconnected.
04 F1 DA CE exhaust temperature error or DE exhaust
temperature error is detected.
04 F1 DB CE intake temperature error or DE intake temperature
error (sensor failure) is detected.
04 F2 06 CM EXP is disconnected.
04 F2 08 CM DI port is disconnected.
04 F2 09 CM SAS port is disconnected.
04 F2 0A CM BE Expander port is disconnected.
04 F2 0B CM memory is disconnected.
04 F2 0C CM Flash ROM is disconnected.
04 F2 0E NAND Controller is disconnected.
04 F2 0F SCU is disconnected.
04 F2 11 CM Port is disconnected.
04 F2 12 CM FE Expander is disconnected.
04 F2 13 CM FE Expander Port is disconnected.
04 F8 00 Pinned Data occurs. This sense code is notified when the
relevant event occurs.
06 11 90 Writing of Bad Data (data lost identifier) occurs. These sense codes are notified when
"RAID Degradation Event" is enabled
for Warning Level in the event
notification setting.
They are not notified during
maintenance operations.
06 F2 80 Rebuilding to a hot spare is performed. These sense codes are notified when
"RAID Recovery Event" is enabled for
Warning Level in the event notification
setting.
They are not notified during
maintenance operations.
06 F2 81 Rebuilding to a Disk Drive is performed.
06 F2 82 Rebuilding to a hot spare is complete.
06 F2 83 Rebuilding to a Disk Drive is complete.
06 F2 84 Copyback starts.
06 F2 85 Copyback is complete.
06 F2 88 Rebuilding to a hot spare or a replaced disk is
complete, but Bad Data (data lost identifier) exists.
These sense codes are notified when
"RAID Degradation Event" is enabled
for Warning Level in the event
notification setting.
They are not notified during
maintenance operations.
06 F2 8A Rebuilding to a disk is halted.
06 F2 8B Rebuilding to a replaced disk is halted.
06 F2 8C Copyback is halted.
06 F2 8D Copyback is halted because an error is found in the
copy source disk.
06 FB 01 CM error is detected. These sense codes are notified when
"Module reported a Warning" is
enabled for Warning Severity Level in
Setup Event Notification.
They are not notified during
maintenance operations.
06 FB 06 CM BE Expander is detected.
06 FB 08 CM DI Port error is detected.
06 FB 09 CM SAS Port error is detected.
06 FB 0A CM BE Expander Port error is detected.
06 FB 0C CM Flash ROM error is detected.
06 FB 0E CM NAND Flash error is detected.
Sense code
Description Remarks
SK ASC ASCQ