A.2.3 Warning Messages
This section describes the messages that are sent when the severity is Warning.
Warning message list
The following messages are sent when components require maintenance or preventive mainte-
nance, when the battery reaches its expiration date, for unusual temperatures, and for other
warning events.
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID (*1) Lower: Description
J 01SSMM00 5 0100MM00 0xww Controller Module#m(zz xxHz) Warning factor(ww)
<pppppppppppp ssssssssss rrrrr>
These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.
CM error other than above is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
ww: Factor code
pp...: Component number
ss...: Serial number
rr...: Version
J 06SSMM00 5 0600MM00 0x00 Controller Module#m(zz xxHz) BE Expander
Warning <pppppppppppp ssssssssss rrrrr>
CM BE Expander error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
J 08SSMM0p 5 0800MM0p 0x00 Controller Module#m(zz xxHz) DI Port#p Warning
<pppppppppppp ssssssssss rrrrr>
CM DI Port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m
: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number