Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
115
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
When the event type is "R"
The following messages are sent when a normal state is restored for Error or Warning level
events.
*1: This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26.
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID
(*1)
Lower: Description
R 06SSMM00 25 0600MM00 0 Controller Module#m(zz xxHz) BE Expander Normal
<pppppppppppp ssssssssss rrrrr>
These messages
are notified when
"Recovery from
Error" is enabled for
Warning Level in the
event notification
setting.
They are not notified
during maintenance
operations.
Normal status is restored for a CM BE Expander
error.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
R 90SSddnn 25 9000ddnn 0 Expander DE#dd/EXP#n Normal <pppppppppppp
ssssssssss rrrrr>
Normal status is restored for a DE Expander error.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
nn: Port number (00 – 01)
n: EXP number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
R D2SSdd0n 22 D200dd0n - Power Supply Unit DE#dd/PSU#n Normal
<pppppppppppp ssssssssss rrrr>
Normal status is restored for a PSU error.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
n: PSU number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
R DASSdd00 26 DA00dd
00 0 DE OUT TEMP Normal
Normal status is restored for a CE exhaust
temperature error or DE exhaust temperature error.
dd: DE-ID ("00" for a controller enclosure)
R DBSSdd00 26 DB00dd00 0 DE IN TEMP Normal
Normal status is restored for a CE intake
temperature error or DE intake temperature error.
dd: DE-ID ("00" for a controller enclosure)