Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
116
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
A.2.5 Test Messages
The messages that are sent when the test notification of an event is performed in ETERNUS
Web GUI or ETERNUS CLI are described below.
Send Test E-Mail
The message is notified when the test notification of e-mail is performed in ETERNUS Web GUI
or ETERNUS CLI.
Test Trap transmission
The message is notified when the test notification of the SNMP Trap is performed in ETERNUS
Web GUI or ETERNUS CLI.
A.2.6 Sense Codes
This section describes the sense codes that are notified to the server.
Event type and event code Message
T FFFFFFFF Test E-mail Message
Trap No. TrapItemId TrapMessage
2 0x80000000 SNMP Trap Test
The Trap No. and ItemId in the test Trap are the same as the notification
that is sent when the disk in Slot#0 of DE#00 is in Fault status. A disk is not
actually disconnected when a test Trap is notified.
Sense code
Description Remarks
SK ASC ASCQ
02 04 00 The device is in Not Ready status. This sense code is notified when the
relevant event occurs.
04 F1 01 CM is disconnected. These sense codes are notified when
"Module was broken" is enabled for
Error Severity Level in the event
notification setting.
They are not notified during
maintenance operations.
04 F1 1A SFP is disconnected.
04 F1 80 3.5 inch Disk is disconnected. These sense codes are notified when
"Disk was broken" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during
maintenance operations.
04 F1 81 2.5 inch Disk is disconnected.
04 F1 88 Disk is disconnected because an error occurred during
the Write check of the disk patrol.
These sense codes are notified when
the relevant event is detected during
Disk Patrol.