Fujitsu DX60 Portable Media Storage User Manual


 
Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
105
Copyright 2012 FUJITSU LIMITED P3AM-5512-03ENZ0
J 81SSddNN 5 8000ddNN 0x00 Disk Drive DE#dd-Disk#nn(SAS xxxGB yykrpm
ccccccc) Warning <pppppppppppp ssssssssssss
rrrr>
These messages
are notified when
"Disk reported a
Warning" is enabled
for Warning Level in
the event
notification setting.
They are not notified
during maintenance
operations.
2.5 inch Disk error is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
NN: Disk slot number (0 – 17 (hexadecimal))
nn: Disk slot number (0 – 23 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot spare
(Spare))
pp...: Component number
ss...: Serial number
rr...: Version
J 90SSdd0n 5 9000dd0n 0x00 Expander DE#dd/EXP#n Warning <pppppppppppp
ssssssssss rrrrr>
These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.
DE Expander error is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
n: EXP number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
J 91SSddnp 5 9000ddnp 0x00 Expander Port DE#dd/EXP#n/Port#p Warning
<pppppppppppp ssssssssss rrrrr>
DE Expander Port error is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
p: Port number (0 – 1)
n: EXP number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
J C1MM0000 5 0100MM00 0x00 Controller Module#m(zz xxHz) Reboot
<pppppppppppp ssssssssss rrrrr>
CM is rebooted.
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
Event type
and event
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID (*1) Lower: Description