A SERVICE OF

logo

3-30
Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide
OL-29284-01, Release 6.x
Chapter 3 Configuring Fibre Channel Interfaces
Configuring Fibre Channel Interfaces
Use the show interface command to verify the port speed configuration for an interface on a 4-Gbps or
8-Gbps Fibre Channel switching module.
switch# show interface fc 9/1
fc9/1 is up
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 22:01:00:05:30:01:9f:02
Admin port mode is F
snmp traps are enabled
Port mode is F, FCID is 0xeb0002
Port vsan is 1
Speed is 2 Gbps
Rate mode is shared
Transmit B2B Credit is 64
Receive B2B Credit is 16
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
226 frames input, 18276 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
326 frames output, 21364 bytes
0 discards, 0 errors
0 input OLS, 0 LRR, 1 NOS, 0 loop inits
3 output OLS, 2 LRR, 0 NOS, 0 loop inits
16 receive B2B credit remaining
64 transmit B2B credit remaining
Configuring Rate Mode
Restrictions
Changing port speed and rate mode disrupts traffic on the port.
Detailed Steps
To configure the rate mode (dedicated or shared) on an interface on a 48-port or 24-port 4-Gbps, or any
8-Gbps Fibre Channel switching module, follow these steps:
Command Purpose
Step 1
switch# config t
switch(config)#
Enters configuration mode.
Step 2
switch(config)# interface fc 1/1
switch(config-if)#
Selects the interface and enters interface
configuration submode.