MISCELLANEOUS
The AIR series are unquestionably high quality
products. This section focuses on a few technical
issues that adds to the perception of the high standard
of the products.
High efficiency compact Switched Mode Power Supply
(SMPS)
For saving overhead power consumption and to insure
optimal performance disregarding the mains voltage, the
unit is equipped with a high efficiency compact Switched
Mode Power Supply (SMPS). Using switched technology
both in amplifiers and power supply can reduce the heat
sink size to about 1/3 the size of what it would be with
regular power supply and class AB amplifiers.
Power saving shut down modes
The amplifier can detect whether or not there is Input on
the analog or digital line. If input is absent for more than
half an hour all monitors in a network will go to sleep-
mode. from which they can recover automatically when
signal is received. The power up time from sleep is a few
hundred ms.
If Input signal is absent for more than 2½ hours the system
will go into standby from which it can recover by user
intervention such as touching the volume wheel on the
Remote Control or by touching the Master monitor display.
Software updates
Each monitor in a setup can be software updated via
Network. This is done through PC/Mac using the AIR
SOFT. Follow the Software update procedure as described
on www.dynaudioacoustics.com
Reset Procedures
Three different levels of “Reset” exists. For all three
scenarios all connected monitors will be affected.
The following Reset procedures are accessed by
holding the ENTER key on the System Controller while
powering up:
Clear Monitor Settings
All global and local parameters in connected monitors are
reset. Preset and network settings are not affected.
Reset all Settings
A “factory” reset procedure that deletes all global and local
parameter settings as well as preset and network settings.
The following reset procedure is found in the Setup
menu:
Clear Setup for entire network
Select this reset procedure to clear all network settings.
Global Parameters
These parameters applies for the entire System:
Global parameters stored with presets
Bass Management
Mute Status
Global parameters NOT stored with presets
Ref. Levels
Analog Input Sensitivity
Selected Setup
BNC Sync
Local Parameters
These parameters applies for individual
monitors:
Local parameters stored with presets
X-Curve
Parametric EQ setting (set via AIR PC-IP)
LFE Gain (subs)
LFE Low Pass (subs)
Rel. Level
Local parameters NOT stored with presets
Bass and Treble
Delay
Lock status (set via AIR PC-IP)
Room position
Calibration Level
Tasks
Phase (Subs)
Polarity (Subs)