10
SETUPS
6.1 Analog Setup
This illustration shows how to connect a 6.1 Analog
setup
Left is set as System Controller by leaving out
the TC
Link button on the rear panel.
Left monitor receives both the Left and Right signal. The
Right monitor is fed via the TC LINK RJ-45 connection
form Left to Right.
Center monitor receives both Center and LFE signal. The
LFE monitor is fed via the TC LINK RJ-45 connection
from Center to LFE.
Left Surround monitor receives both LS and RS signal.
The RS monitor is fed via the TC LINK RJ-45 connection
from LS to RS.
The Center Surround monitor receives only Center
Surround signal.
Center Chain:
From software 1.10 it is possible to
connect one or more Center Chain monitors.
Channels must be connected as follows:
- Left channel to Left Input on Left monitor.
- Right channel to Right Input on Left monitor.
- Center channel to Left Input on Center monitor.
- LFE channel to Right Input on Center monitor.
- Left Surround channel to Left Input on Left Surround
monitor.
- Right Surround channel to Right Input on Left
Surround monitor.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
5.1 Dig/6 - Master
This is a 5.1 digital setup with Bass Management as an
option. The setup requires one Master monitor with the
optional Digital AES/EBU Input Card installed, four
Slave monitors (or Masters set as Slave) and one Sub.
Center monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
Center monitor receives all 6 channels on the three
AES/EBU connections.
- Center and LFE on the monitors Digital IN connection.
- Left and Right on the I/O cards Digital IN no. 2.
- LS and RS on the I/O cards Digital IN no. 3.
Right, Left, Sub, LS and RS receives signal via TC LINK
RJ-45 connections from the Center Master monitor.
Clock MUST be sent on the AES connection feeding
Center/LFE channels (or on BNC).
With Bass-management “off” only the LFE signal is fed to
the Sub.
With Bass-management activated, Low Frequency
information below the set Cross-over frequency from the
5 main channels is extracted and distributed to the Sub
where it is summed with the LFE channel.
The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
With Bass-management “off” only the LFE signal is fed to
the Sub.
With Bass-management activated, Low Frequency
information below the set Cross-over frequency from the
5 main channels is extracted and distributed to the Sub
where it is summed with the LFE channel.
The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.