A SERVICE OF

logo

5-5
Catalyst 2955 Hardware Installation Guide
78-14944-03
Chapter 5 Troubleshooting
Diagnosing Problems
No connectivity. Incorrect or bad cable.
No link at both ends.
A crossover cable was used
when a straight-through was
required, or vice-versa.
For the correct pinouts and
the proper application of
crossover vs.
straight-through cables, see
the Cable and Adapter
Specifications section on
page B-5.
The cable is wired incorrectly. Replace it with a tested
good cable.
STP checking for possible
loops.
Wait 30 seconds for port
status LED to turn green.
Unreadable characters on
the management console.
Incorrect baud rate. Reset the terminal-emulation
software to 9600 baud.
System LED (Uplink port
status 13 LED) is amber,
and all port LEDs are off.
Corrupted software. Attach a monitor to the serial
port to display the switch boot
loader. For more information,
see the switch software
configuration guide.
System LED (Uplink port
13 LED) is amber.
Fatal POST error detected. Contact Cisco Systems.
Table 5-1 Common Problems and Solutions (continued)
Symptom Possible Cause Resolution