Sony PCM-M1 MP3 Player User Manual


 
Recording24
EN
Recording from audio equipment with
digital output (Digital connection)
1 Use and connect the optical cable or coaxial cable
according to the digital output jack of the
connected equipment.
2 Set the INPUT SELECT switch of the connecting
cable to DIGITAL.
3 Press the r REC and P PAUSE buttons.
4 Press either the ( PLAY or P PAUSE button to
begin recording. Then, begin playback of the
connected source.
Source and sampling frequency for recording
When recording with digital connection, the sources
will be automatically recorded in its own sampling
frequency shown below.
Source Sampling frequency
Broadcasting satellite B mode 48 kHz
audio, DAT SP mode
CD, MD, DAT SP mode 44.1 kHz
Broadcasting satellite A mode 32 kHz
audio, DAT LP mode
To make a digital backup copy
When you want to make backup copies of recordings
of your live performance etc., record with digital
connection on this recorder. Copying is possible
regardless of the copy code on the source. The copy
code on the backup is in accordance with SCMS
(pages 28, 44).
Notes
Use only the
recommended digital
cable (not supplied).
(see page 53)
You cannot use the
POC-DA12/DA12M/
DA12S or RK-DA10
digital connecting
cables with this unit.
Make sure to set the
INPUT SELECT switch
of the connecting cable
to DIGITAL before
recording. Switching it
during recording will
create a short blank in
the recording.
Tips
•In digital connection,
note the following:
– Setting the recording
mode is not required.
– The recording level is
set automatically to the
level of the source.
Manual adjustment is
not available in this
case.
The recorder supports
input in IEC958 format.
Adjustment of the copy
code (ID 6) is possible
when recording input
in this format (page 28).
The recorder does not
support AES/EBU
format.
Setting of the SP•LP
switch is applicable
when recording a 32 kHz
source only. (When set to
SP, the source is
recorded in the 32 kHz
SP mode. When set to
LP, the source is
recorded in the 32 kHz
LP mode.)
Other sources will be
automatically recorded
in its own sampling
frequency regardless of
the SP•LP switch.
to REMOTE
DIGITAL I/O
Coaxial cable
RK-DA10P
(not supplied)
Optical cable
POC-DA12P
POC-DA12MP
POC-DA12SP
(not supplied)
INPUT
SELECT
to (OPTICAL)
digital output
CD player,
BS tuner,
DAT deck,
MD deck,
etc.
to (COAXIAL)
digital output
or
PCM-M1