Heater rated power:
MAIN:550 ± 27.5W (120VAC/230VAC)
SUB :330 ± 15.0W (120VAC/230VAC)
Thermostat contact open temperature: 180 ± 5°C
Signal line name Description
RHV Data on humidity inside the device (analog value)
TH2 Data on temperature inside the device (analog value)
EEPROM DATA Control signal of EEPROM
EEPROM CLOCK Control signal of EEPROM
NSC VD
Data on temperature of the temperature control sensor (analog
value)
NSC VC
Data on temperature of the temperature control sensor (analog
value)
FUSER STS
Data on temperature of the high temperature detection sensor
(analog value)
HEAT1
Control signal for Main Lamp placed in FUSER ASSY (LAMP
lights up at "High:HEAT1 and "Low:xHEAT1")
xHEAT1
HEAT2
Control signal for Sub Lamp placed in FUSER ASSY (LAMP
lights up at "High:HEAT1 and "Low:xHEAT1")
xHEAT2