A SERVICE OF

logo

Chapter 6 Principles of Operation
6 – 30
3.4 Inner Duplex Assembly
3.4.1 Major functions
- AUTOMATIC DENSITY CONTROL (ADC) SENSOR
Reads the density of the toner image prepared on the surface of BTR in the TRANSFER ROLLER
(refer to "3.6 Transfer Roller & Fuser") and feeds it back to the process control (refer to "5.4 Process
Control").
- SENSOR TONER FULL
Detects that the toner collect space in the TRANSFER ROLLER (refer to "3.6 Transfer Roller &
Fuser") has become full of waste toner to be collected.
- DRIVE ASSY FUSER
Supplies the drive to the FUSER (refer to "3.6 Transfer Roller & Fuser").