A SERVICE OF

logo

1 – 27
Chapter 1 Troubleshooting
FIP-3 001-362/001-364/001-365/001-366 Restart Printer
Possible causative parts:FAN LV (PL1.1.33)
LVPS (PL9.1.6)
PWBA MCU (PL9.1.16)
Replace the PWBA MCU.
(RRP9.7)
NoYes
Checking the FAN LV
Does the FAN LV function normally?
Checked by [Digital Output] - [DO-42]
in [IOT Diagnosis].
In the test, close the INTERLOCK
SWITCH.
Checking after replacing
the FAN LV
Replace the FAN LV.
(RRP1.13)
Does the error still
occur when turning
on the power?
NoYes
END
Checking after replacing
the PWBA MCU
Replace the PWBA MCU.
(RRP9.7)
Does the error still
occur when turning
on the power?
NoYes
END
Replace the LVPS.
(RRP9.3)
Reseat the FAN LV.
(RRP1.13)
Does the error still
occur when turning
on the power?
NoYes
END