Chapter 1 Troubleshooting
FIP-57 Close Front Door 077-300
Does the error still
occur when turning
on the power?
NoYes
Possible causative parts:COVER ASSY FRONT HEAD (PL1.1.6)
COVER ASSY TOP PHD (PL1.1.8)
LVPS (PL1.1.6)
HARNESS ASSY INTERLOCK (PL9.1.11)
Checking the HARNESS
ASSY INTERLOCK
Checking the Interlock Switch
Mechanism
Open and close the Front Cover.
No
Checking the COVER
ASSY FRONT HEAD
END
Does the number on the screen
increase by one, every time the
Front Cover is operated?
Checked by [Digital Input] - [DI-7]
in [IOT Diagnosis].
Yes
END
Are there any
damages on the
COVER ASSY
FRONT HEAD?
NoYes
Replace the COVER
ASSY FRONT HEAD.
(RRP1.3)
Checking the COVER
ASSY TOP PHD
Are there any
damages on the
COVER ASSY TOP
PHD?
NoYes
Replace the COVER
ASSY TOP PHD.
(RRP1.4)