A SERVICE OF

logo

2 - 19
Chapter 2 Operation of Diag.
- About Diag. Matrix
The diagnosis number differs depending on the composition of the Optional Feeder(s) that was
installed to the printer. Refer to Diag Matrix table below.
Diag Matrix for Tray 1/2/3/4 No Paper Sensor (DI-11/-12/-13/-1e)
Diag Matrix for Cassette 1/2/3/4 Size Sensor (DI-38/-40/-48/-50)
Printer
Paper Tray Composition
Standard Only
One Tray Opt.
Feeder
Two Tray Opt.
Feeder
One Tray +
Two Tray Opt.
Feeders
1. Standard DI-11 DI-11 DI-11 DI-11
2. 500 Sheets
(One Tray Opt. Feeder)
-- DI-12 -- DI-12
3. 500 Sheets -- -- DI-12 DI-13
4. 500 Sheets
(Two Tray Opt. Feeder)
-- -- DI-13 DI-1e
Printer
Paper Tray Composition
Standard Only
One Tray Opt.
Feeder
Two Tray Opt.
Feeder
One Tray +
Two Tray Opt.
Feeders
1. Standard DI-38 DI-38 DI-38 DI-38
2. 500 Sheets
(One Tray Opt. Feeder)
-- DI-40 -- DI-40
3. 500 Sheets -- -- DI-40 DI-48
4. 500 Sheets
(Two Tray Opt. Feeder)
-- -- DI-48 DI-50