2-132
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter 2 Alarm Troubleshooting
2.7.221 SSM-ST4
Note SSM-ST3E is an informational condition. It does not require troubleshooting.
2.7.221 SSM-ST4
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: BITS, DS1, NE-SREF, OCN
The SSM Stratum 4 (ST4) Traceable condition occurs when the synchronization message quality level
is lowered to ST4. The message quality is not used because it is below ST3.
Note SSM-ST4 is an informational condition. It does not require troubleshooting.
2.7.222 SSM-STU
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: BITS, DS1, NE-SREF, OCN
The SSM Synchronization Traceability Unknown (STU) condition occurs when the reporting node is
timed to a reference that does not support SSM, but the ONS 15310-CL or ONS 15310-MA has SSM
support enabled. SSM-STU can also occur if the timing source is sending out SSM messages but SSM
is not enabled on the system.
Clear the SSM-STU Condition
Step 1 In node view, click the Provisioning > Timing > BITS Facilities tabs.
Step 2 If the Sync. Messaging Enabled check box for the BITS source is checked, uncheck the box.
Step 3 If the Sync. Messaging Enabled check box for the BITS source is not checked, check the box.
Step 4 Click Apply.
Step 5 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1-800-553-2447).
2.7.223 SSM-TNC
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: BITS
The SSM Transit Node Clock (TNC) Traceable condition occurs when the synchronization message
quality level is changed to TNC.
Note SSM-TNC is an informational condition. It does not require troubleshooting.