A SERVICE OF

logo

EPSON Stylus Color 900 Revision C
Disassembly and Assembly Disassembly Procedures 110
4.2.5 Shield Plate on the C265 Main Board Removal
1. Remove the C265 Main board. (See Section 4.2.3.)
2. Remove the remaining four connectors from the relay board. (See
Figure 4-5 when connecting them.)
3. Remove two screws securing the right upper main shield plate to
the bottom frame and another two screws securing the left upper
main shield plate to the bottom frame, then remove the both plates
together.
Figure 4-8. Shield Plate Removal (1)
4. Disconnect the FFC from the connector CN15 on the C265 Main
board.
5. Remove two screws securing the shield plate (top) to the bottom
frame, and remove the shield plate (top).
6. Remove the Type-B interface guide.
7. Remove four screws securing the C265 Main board onto the bottom
frame. (Two screws among the four are fixing the reinforcing plate
for the Type-B interface guide.)
8. Viewing the C265 Main board from the Centronics I/F connector
side, remove four small screws and remove the C265 Main board.
Figure 4-9. Shield Plate Removal (2)
Screws securing the
Screws securing the
Left Upper Main Shield Plate
Right Upper MainShield Plate
Type B I/F Guide
CN15
Shield Plate (top)
Screws securing the
Shield Plate (top)
Left Upper Main Shield Plate
Right Upper Main Shield Plate
Screws securing the C265 Main Board