Tag Switching 9-25
Checking and Troubleshooting
Checking and Troubleshooting
Use the following procedure as a quick checkout of the tag switching configuration and operation
with respect to the BPX switch.
Step 1 Wait a while, and check whether the controller sees the interfaces correctly;
on the TSC, enter the following command:
tsc# show controllers VSI descriptor
and the an example output is:
Note Check the TSC on-line documentation for the most current information.
Phys desc: 4.1
Log intf: 0x00040100 (0.4.1.0)
Interface: slave control port
IF status: n/a IFC state: ACTIVE
Min VPI: 0 Maximum cell rate: 10000
Max VPI: 10 Available channels: 999
Min VCI: 0 Available cell rate (forward): 100000
Max VCI: 65535 Available cell rate (backward): 100000
Phys desc: 4.2
Log intf: 0x00040200 (0.4.2.0)
Interface: ExtTagATM2
IF status: up IFC state: ACTIVE
Min VPI: 0 Maximum cell rate: 10000
Max VPI: 10 Available channels: 999
Min VCI: 0 Available cell rate (forward): 100000
Max VCI: 65535 Available cell rate (backward): 100000
Phys desc: 4.3
Log intf: 0x00040300 (0.4.3.0)
Interface: ExtTagATM3
IF status: up IFC state: ACTIVE
Min VPI: 0 Maximum cell rate: 10000
Max VPI: 10 Available channels: 999
Min VCI: 0 Available cell rate (forward): 100000
Max VCI: 65535 Available cell rate (backward): 100000
-------
Step 2 If there are no interfaces present, first check that card 4 is up,
with, on the BPX switch:
dspcds
and, if the card is not up:
resetcd 4 h
and/or remove the card to get it to reset if necessary.
Note This example assumes that the controller is connected to card 4 on the switch. Substitute a
different card number, as applicable.