I-Data i-data Electronic Documentation ida Portable Media Storage User Manual


 
Error Messages
ida FS 250, Operator's Guide
-46-
10. Errors and Recovery
Printer-related error messages will be displayed on the printer front panel. To
recover from these errors, please refer to the relevant printer documentation.
The following errors are related solely to the ida FS 250 and will appear as
printed error messages. For some of the error messages, additional
explanatory text may be printed out together with the error message.
10.1 ida FS 250 Error Messages
Error 8008 - Attention ! Two devices on the same address
Escape Sequence Error Invalid ESC sequence has been sent
to the printer (see the section: Invalid
Escape Character)
Error 4510 Invalid SCS Control received
Error 5004 Initializing NVRAM
Error 5005 NVRAM failed
Error 5006 NVRAM initialized
Error 50?? CP Error
In addition to the above messages, a number of Boot Error Messages may
be generated.
10.1.1. Two Devices with Same Address
If two devices on the same twinax line has the same address, the printer will
print an error message. To recover follow these steps:
1. Turn the power off
2. Check each device on the same line against the system configuration.
3. Change the device address accordingly.