I-Data i-data Electronic Documentation ida Portable Media Storage User Manual


 
Specifying Share Timeout and String
ida FS 250, Operator's Guide
-25-
%X1
NOTE: %X1 will delete the temporary escape character.
The FSL string above was split up into several lines for reasons of
clarification to simplify the explanation of the different functions. Below is an
example where the FSL string is typed in one line.
Example:
&&??%%Y100,30,1B,45%%X1
The FSL string above has the following effect:
Defines % as ESC character
Sets timeout to 30 seconds
Send 1B 45 HEX (RESET) before the next data transmission.
Saves setup in the NVRAM and deletes "%" as escape character
NOTE:
FSL 100 works on the port it is sent to. If it is sent to the parallel or serial
input port, the string containing the Function 100 programming will be
printed when it is sent to the ida FS 250.