5. Specifying Share Timeout and String
In order to specify the timeout for a specific input port, an FSL ( Function
Selection via the Line) sequence must be sent to the port in question. To do
this a temporary Escape (ESC) Character must be defined first. This is done
in the following way:
&&??<character>
The sequence "&&??%" will define " %" as the ESC Character.
Timeout is specified in FSL Function 100 . This function has the following
syntax ("%" is the ESC Character):
%Y100,<timeout>[,user string]%
Factory default = 20 seconds
Timeout: 1 to 255 indicating number of seconds
User string: Optional - string in HEX to be sent to the
printer before transmission of data, when the
printer is selected by the share unit.
If function 100 is sent to the twinax, a user
string number can be defined instead of a
HEX string. The user string then has to be
defined in function 61.
NOTE:
The Timeout string must be written in ONE line (see example below).
The user string and settings will only be sent if a share condition has
occurred.
The new setup must be saved in the NVRAM with the following command
("%" is the ESC Character):