I-Data i-data Electronic Documentation ida Portable Media Storage User Manual


 
Connecting to System
ida FS 250, Operator's Guide
-20-
If all three (a. b. and c.) are in order, contact your systems support personnel
or your point of purchase.
3.5.1 Testing
The test printout pages can be generated in two ways - via the address switch
or via the line activating the T function . For details on the T function, please
see the section: Quick Reference Guide of the Supported FSL Functions.
Test via the address switch
1. Turn the address switch to the "T" position. A settings printout will be
generated (test 4).
2. Turn the switch away from the T-position.
3. When the CU indicator flashes, turn the switch back to the T-position.
4. The printer will now enter Online HEX Dump mode and print all data
received in on-line HEX dump format ( test 1).
5. Hex dump mode is terminated by turning the address switch to its power up
position.
Keep the settings printout together with this manual for future reference.
Finally, a settings printout can also be generated at power on by activating
function Y120. See the Section: Quick Reference Guide of the Supported
FSL Functions for details.
NOTE:
When installing the interface, it is recommended that you carry out Test
4, Settings Printout, to check whether the printer is set to the correct
language. If the language is incorrect, contact your systems support or
your point of purchase.