HP (Hewlett-Packard) XP10000 Portable Media Storage User Manual


 
Auto LUN XP user guide for the XP12000/XP10000 47
2342 Migration target volume is already specified as
an Auto LUN XP target volume.
Release the Auto LUN XP volume, and perform the
volume migration.
2344 Volume specified by the migration cancellation is
not a migration target volume.
RAID Manager is trying to perform the migration
cancellation for a pair that is not migrating.
Check the configuration definition file.
2346 Migration target volume is a Continuous Access
XP primary volume.
Release the Continuous Access XP pair, and
perform the volume migration.
2347 Migration target volume is a Continuous Access
XP secondary volume.
Release the Continuous Access XP pair, and
perform the volume migration.
234B Migration target volume is already specified as
an Auto LUN XP source volume.
Release the volume from Auto LUN XP, and
perform the volume migration.
2355 Volume Management setting in the migration
target and source volumes is different.
Volume migration cannot be executed. Check the
configuration definition file.
2356 Migration target volume is being used with Flex
Copy XP.
Release the Flex Copy XP pair, and perform the
volume migration.
2362 Migration source volume is an XRC primary
volume.
Release the XRC pair, and perform the volume
migration.
2363 Migration target volume is an XRC primary
volume.
Release the XRC pair, and perform the volume
migration.
2366 Migration target volume is a Concurrent Copy
primary volume.
Release the Concurrent Copy pair, and perform
the volume migration.
2368 Migration source volume is a Continuous Access
XP primary volume that is not in the SUSPEND
status.
Put the Continuous Access XP pair in the
SUSPEND status or release the Continuous Access
XP pair, and perform the volume migration.
236B Migration source volume is a Business Copy XP
volume that is in the SP-PEND status.
Perform the volume migration after the Business
Copy XP pair is changed to the SPLIT status.
2372 Migration source volume is being formatted. Perform the volume migration after formatting is
completed.
2373 Migration source volume is a command device. Volume migration cannot be executed. Check the
configuration definition file.
237C Migration source volume is an external volume
specified as a Continuous Access XP primary
volume.
Release the Continuous Access XP pair, and
perform the volume migration.
237E Specified pair is being used with Flex Copy XP. Release the Flex Copy XP pair, and perform the
volume migration.
2382 Migration target volume is being formatted. Perform the volume migration after formatting
completes.
2383 Migration target volume is a command device. Volume migration cannot be executed. Check the
configuration definition file.
2389 Cache LUN XP is set on the migration source
volume.
Release the Cache LUN XP setting, and perform
the volume migration.
238A Cache LUN XP is set on the migration target
volume.
Release the Cache LUN XP setting, and perform
the volume migration.
238B Migration source and target volumes are
specified as LUSE volumes.
Volume migration cannot be executed. Check the
configuration definition file.
Table 13 Errors during Auto LUN XP migrations or migration cancellations using RAID Manager
Error code Cause Solution