Requirements
The DMP-100 processor should no t be placed in a built-in installation or enclosure unless pr oper ventilation is provided.
When using the unit in a multi unit rack assembly or closed assembly, the ambient temperature inside the assembly may not
exceed the rated ambient temperature (0 -50°C) of the processor. The installation should be such that the amount of air ow
required for safe operation of the equipment is not compromised.
When building in the DM P- 100 processor into a rack with cover door, be aware that a space of minimum 85 mm is needed
between the indicated reference and the cover door. This space is needed to guide the input cables to the inputs.
Image 3-1
The front side of the DMP-100 processor is considered as reference for this installation requirement.
The DM P- 100 processor w ill require that air ow s freely in vent holes. Blocking these holes will greatly reduce the r eliability of
the unit and lead to the possibility of overheating.
The DMP -100 processor should operate from an AC
power source. The DMP -100 processor is equipped with an auto-ranging
power supply from 100 to 240 volt (50–60 Hertz).
When installed in a rack, the mounting should be such that no hazardous c ondition is achieved due to uneven mechanical
loading.
When the mains switch located on the back of the DM P- 100 processor is not accessible due to rack mo unting, the soc ket outlet
supplying the rack shall be installed near the equipment and be easily accessible or a readily accessible disconnect devic e shall
be incorporated in the xed wiring. When using a rack in an installation it is advisable to log the serial number of the device and
to activate the warranty gure by registering utilizing the included form.
Do not place the DMP-100 processor on an unstable cart, s tand or table. The device may fall, causing personal injury and
serious damage to the processor.
The data path between the DMP-100 processor and the LED display may not exceed ten (10) meter.
R59770263 DMP-100 15/09/2011