A SERVICE OF

logo

23
Long Coupled Mounting Frame Assembly
On VF10 to VF50 LC pumps, a mounting frame adaptor kit is needed to convert the close-
coupled frame into a long coupled frame and yet maintain the current long coupled footprint.
The centre floor-mounting hole becomes redundant but can be used for additional fixing. The
assemblies are simple bolt on parts of which an example is shown in figure 7a / 7b below
Figure 7a
Figure 7b
Figure 7b shows the extension plate in place and the slots aligned to accept the base plate
mounting bolts.
Lift the pump upright to stand on its frame using the lifting eye provided and the appropriate
lifting equipment
The flange should be coated with a thin protective film of anticorrosion treatment, this does
not need to be removed before fitting the gasket. (if the pump has been cleaned during
preparation then a light film of grease or gasket sealant should be applied)