V. TROUBLESHOOTING
LIFT WILL NOT OPERATE
" Check the circuit breaker reset button. Reset if nec-
essary. See figures 21 and 22.
" Ensure all harness connections are secure.
" Ensure the power wire leading to the positive
battery terminal is tight and not corroded.
" Check the fuse located on the red power wire near
the battery. If blown, replace with a new 25-amp
fuse. See figure 23.
WARNING! Do not use a higher rated
fuse than 25-amp. Doing so may
damage the lift’s electrical system.
WARNING! The replacement fuse
must exactly match the rating of the
old fuse. Failure to use properly rated
fuses may cause damage to the
electrical system.
LIFT STOPS OPERATING
If your SilverBoom is heavily strained because of ex-
cessive loads, the main circuit breaker (see figures
21 and 22) may trip to protect the motor and electron-
ics from damage. When the breaker trips, the entire
electrical system shuts down.
WARNING! Never attempt to lift more
than 300 lbs. (136 kg) with the
SilverBoom 300.
To reset the main circuit breaker:
1. Allow a minute or so for the electronics to “cool.”
2. Push in the reset button to reset the breaker.
If the breaker trips frequently, contact your authorized
Pride Provider.
Figure 23. Fuse Replacement
WORKING FUSE BLOWN FUSE
CIRCUIT BREAKER RESET BUTTON
Figure 21. Circuit Breaker Reset Button SilverBoom 300
CIRCUIT BREAKER RESET BUTTON
Figure 22. Circuit Breaker Reset Button Power Rotating