IBM 760XD (9547) Clock Radio User Manual


 
Undetermined Problems
Use the following procedure when the diagnostic tests do
not identify the failing adapter or device.
Check that all cables, wires, and connectors are connected
so that they do not cause a short circuit. If any problems
are found, reconnect or replace them.
Check the power supply for correct operation (see “Power
Supply” on page 552). If the power supply is operating
correctly, return here and continue with the following
procedures.
1. Power-off the computer.
2. Remove or disconnect one at a time the following
adapters or devices from IBM ThinkPad Dock I. (Do
not isolate adapters or devices that are known to be
good.)
a. Non-IBM devices.
b. A modem, printer, mouse, external keyboard,
external display, external diskette drive, numeric
keypad, or other external devices.
c. Any adapter.
Note: Removing an adapter or device may
cause configuration errors. Ignore error
code 174.
d. SCSI device.
e. Hard disk drive.
3. Power-on the system and check if the problem has
changed.
4. If the symptom remains, repeat Steps 1 through 3
until you find the failing adapter or device, or until all
adapters or devices have been removed.
5. If all adapters or devices have been removed and the
problem remains, replace the following IBM ThinkPad
Dock I FRUs one at a time.
Note: If a replaced part did not resolve the problem,
put the original part back in the IBM ThinkPad
Dock I. Do not replace non-defective parts.
a. Riser card
b. Main card
c. IBM ThinkPad Dock I audio card
If the problem goes away when you remove an adapter,
but replacing the adapter does not correct the problem,
replace the main card of IBM ThinkPad Dock I.