IBM 760XD (9547) Clock Radio User Manual


 
Keyboard/TrackPoint Related
Symptoms
Symptom/Error FRU/Action
Keyboard (one or more
keys) does not work.
1. Reseat the three
keyboard cables.
2. Keyboard
3. Keyboard Card
4. System Board
TrackPoint does not work. 1. Go to “TrackPoint III
Checkout” on
page 34.
2. Keyboard
3. Keyboard Card
4. System Board
Pointer moves automatically
or does not work correctly.
1. See “TrackPoint III
Checkout” on
page 34.
Indicator Related Symptoms
Symptom/Error FRU/Action
Indicator incorrectly remains
off or on, but system runs
correctly.
1. Reseat the status
indicator cable.
2. Status Indicator
3. System Board
Battery power status
indicator blinks from green,
yellow, to orange.
1. Check that a correct
battery is installed.
2. Battery Pack
3. DC/DC Card
4. System Board
Power Related Symptoms
Symptom/Error FRU/Action
Power shut down during
operation.
1. Go to “Power
Systems Checkout”
on page 35.
2. Battery Pack
3. Remove the battery
pack and let it cool for
two hours.
4. DC/DC Card
5. Power sources
The system will not
power-off.
1. Remove AC Adapter.
2. Remove the battery.
3. Wait 10 seconds.
4. Reconnect the AC
Adapter and try to
reproduce the error.
5. If the error remains,
replace the System
Board.
ThinkPad 365 (2625) 47