Numeric Error Codes
Symptom/Error IBM ThinkPad Dock I
FRUs
Sequence of Actions
10X, 11X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt
failure.
104.: Protected mode
failure.
105: Last 8042
command not
accepted.
107: NMI test failure.
108: Timer bus test
failure.
109: Low meg-chip
select test.
1. Adapter in slot (if
used)
2. Riser card
3. Main card
195
(The computer was docked
to the IBM ThinkPad Dock I
while in hibernation mode.)
1. Do the following
steps.
a. Power-off and
undock the
system.
b. Power-on and
shut down the
system.
c. Power-off and
dock the system.
1XX See the Hardware
Maintenance Manual of
the computer. If the
problem remains, go to
“Undetermined Problems”
on page 573.
2XX
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. See the Hardware
Maintenance Manual
of the computer.
2. Main card
3XX See “External Keyboard”
on page 556.
566 IBM Mobile Systems - ThinkPad HMM Volume 3