IBM 760XD (9547) Clock Radio User Manual


 
Intermittent Problems
Intermittent system hang problems can be caused by a
variety of reasons that have nothing to do with a hardware
defect, such as: cosmic radiation, electrostatic discharge,
or software errors. FRU replacement should be
considered only when a recurring problem exists.
When analyzing the intermittent problem, do the following:
1. Run the advanced diagnostic test for the system
board in loop mode at least 10 times.
2. If no error is detected, do not replace any FRUs.
3. If any error is detected, replace the FRU shown by
the FRU code. Rerun the test to verify that no more
errors exist.
Undetermined Problems
You are here because the diagnostic tests did not identify
which adapter or device failed, installed devices are
incorrect, a short circuit is suspected, or the system is
inoperative. Follow the procedures below to isolate the
failing FRU (do not isolate nondefective FRUs).
Verify that all attached devices are supported by the
computer.
Verify that the power supply being used at the time of the
failure is operating correctly. (See “Power Systems
Checkout” on page 193.)
1. Power off the computer.
2. Check the cables, wires, and connectors for short or
open circuits. Visually check for damage. If any
problems are found, replace the FRU.
3. Remove or disconnect all of the following devices.
a. Non-IBM devices
b. Devices attached to the expansion bus
connector
c. Printer, mouse, and other external devices
d. Battery pack
e. Hard disk drive
f. Diskette drive
g. DIMM card
h. PC Cards
4. Power on the computer.
5. Determine if the problem has changed.
6. If the problem does not occur again, reconnect the
removed devices one at a time until you find the
failing FRU.
7. If the problem remains, replace the following FRUs
one at a time. Do not replace a non-defective FRU.
Subcard
System board
ThinkPad 380, 380D, 385, 385D (2635)
209