Detailed Descriptions of Installer Menu Items
000 - INSTALLER SEQUENCE
Species entry sequence to the Installer Menu.
0 = 9876 1 = 4321
2 = 1478 3 = 3698
001 - POWER MANAGE (Power Management)
Determines hours of no activity before automatic shutoff. The
Power Management function is for saving energy. If set to 0,
Power Management is Off. Settings range from 0 ~ 7, with 1 ~ 7
representing the hours that the unit will remain ON, unless there
has been activity from either the control panel or remote control.
002 - AC ON (AC Power Switchable)
If set to 1, this allows the TV to turn ON when AC power is applied.
Pressing the POWER button is not necessary. This is desirable if
the TV is plugged into a switched AC outlet (i.e., a set-top box). Set
to 0 (default) for standard TV turn ON/OFF operation.
Note: If set to 1, the TV does not respond to ON/OFF commands
from either the remote or the display panel, and the SLEEP
TIMER is also nonfunctional.
003 - BAND/AFC (Band/Automatic Frequency Control)
There are four possible settings for this option:
0 = Broadcast 1 = CATV (default)
2 = HRC 3 = IRC
If some channels were not found by Auto Tuning (Channel
Search), select the appropriate Band setting here, and add the
channels using the Channel Edit option in the Channel Menu.
004 - STRT CHANNEL (Start Channel)
If active, this function allows you to determine the initial Major
Start Channel number when the TV is turned ON. This feature is
useful for an in-house information channel, since the TV would
always select that channel when it is turned ON. If set to 255,
the last channel tuned before the TV was turned OFF will be the
channel tuned when the TV is turned ON again.
0 = Aux 127 = Map to Major CH 4
1 ~ 125 = Major CH # 255 = Last Channel
126 = Map to Major CH 3
Note: For a digital Start Channel, always remember to set item
104 to the Minor Start Channel number.
Note: 126 and 127 are mapped only in LodgeNet PPV Mode.
005 - CHAN LOCK (Channel Lock)
Channel Lock is ideal if the system must always be on the same
channel. Changing channels with the Channel Up/Down or keypad
numbers is impossible. Channel Lock is inactive if set to 0 (default).
Generally, this feature is used in connection with item 004 STRT
CHANNEL where the Start Channel may, for example, be set to
3 or 4. If the Start Channel is 3, then the TV will remain locked on
channel 3.
NOTE: For items 007, 008, and 009
For legacy reasons, the scale used is 0 - 63. The PTC software
will translate this to the 0 - 100 scale used by the TV.
To translate a TV volume level to the Installer Menu value, use
the following formula:
Installer Value = TV Value x 63
100
Enter only the whole number (disregard fractions).
007 - STRT VOLUME (Start Volume)
This function allows the Installer to determine the initial volume
level setting when the TV is turned ON. This feature is useful for
an in-house information channel, since the TV will always select
that volume level when it is turned ON. The range of values is 0
to 63, 255. If set to 255, the last volume level before the TV was
turned OFF will be the current volume level when the TV is turned
ON again.
008 - MIN VOLUME (Minimum Volume)
This function determines the minimum volume level allowable
with the Volume (VOL) Up/Down control. In this way, for example,
someone cannot set the volume too low to hear. The value range
is from 0 to 63. The factory default is 0, which provides the full
range of volume control, if item 009 MAX VOLUME is set to 63. It
is recommended to set the same value on every TV.
Note: The minimum volume level cannot have a value setting
higher than the maximum volume level (described below).
009 - MAX VOLUME (Maximum Volume)
This function determines the maximum volume level allowable
with the Volume (VOL) Up/Down controls. In this way, for example,
someone cannot set the volume level high enough to disturb
others. The value range is 0 to 63, with 63 as the default, which
gives the user the full range of volume control, if item 008 MIN
VOLUME is set to 0. It is recommended to set the same value on
every TV.
Note: The maximum volume level cannot have a value setting
lower than the minimum volume level (described above).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot
be muted. If set to 0, sound can be muted.
011 - KEY DEFEAT
If set to 1, Key Defeat is enabled, which means that end users
cannot access or navigate within the on-screen menu(s) from the
display front panel, i.e., MENU, OK/ENTER, and menu navigation
buttons on the display panel will not function. Set to 0 to disable
Key Defeat. Note that all IR features remain functional regardless
of this setting.
Installer Menu (Cont.)